Call UsCall Us : 08071930855
Change Language
G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)
G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)
G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)
G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)

G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)

G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator) Specification

  • Purity
  • 99.99% Hydrogen Fuel Input
  • Product Type
  • Hydrogen Fuel Cell Power Generator
  • Material
  • Composite Metal & Engineering Plastics
  • Shape
  • Rectangular Module
  • Moisture
  • Dry, Suitable for Low-Humidity Operation
  • Chemical Composition
  • PEM (Proton Exchange Membrane) Fuel Cell Core
  • Application
  • Portable Power Supply, Outdoor Backup, Remote Telecommunication, R&D Testing
  • Dimension (L*W*H)
  • 405mm x 300mm x 150mm
  • Color
  • Black & Silver
 

G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator) Trade Information

  • Payment Terms
  • Paypal
  • Main Export Market(s)
  • North America, South America, Eastern Europe, Middle East, Central America, Asia
  • Main Domestic Market
  • All India
 

About G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator)

G-HFCS-600W24V(600 W Hydrogen Fuel Cell Power Generator)

Product Code: 1035007

This new hydrogen fuel cell product line is the ideal alternative to the standard portable power generators which use diesel orbatteries. Easy to use and with a smart and compact design, G-HFCS-600W24Vhydrogen fuel cell system produces 600 W of nominal power and brings you fullenergy independence for various applications that require power in the range of0-600 Watts. 

UAVs, robotics applications and other unmanned vehicles,soldier power, and various other military/civilian applications can use thisproduct as a quiet and highly efficient power generator in order to improve theoperational time or flight time or generate power in the field where there isno grid infrastructure. A controller module that manages the startup,shutdown, and all other standard functions of the fuel cell system is includedin the kit.  A DC/DC converter will be required to convert the fuel cellpower into the desired voltage and current values.

You can charge your laptop, smartphone, radios, fans,bluetooth headphones, portable cameras, LED flashlights, battery modules,various camping devices, and many more other portable devices.  A DC/DCconverter will be required to convert the fuel cell power into the desiredvoltage and current values.  

This portable fuel cell system can be easily connectedwith a high purity hydrogen source such as a compressed cylinder from a localgas supplier, hydrogen stored in a composite tank, or a compatible hydridecartridge to get the best performance.

Output Performance:

 NominalPower: 600 W
 Nominal Voltage: 24 V
 Nominal Current: 25 A
 DC Voltage Range: 22 - 36 V
 Efficiency: >50% at the nominal power

Hydrogen Fuel:

 HydrogenPurity: >99.99% (CO content being <1 ppm)
 Hydrogen Pressure: 0.04 - 0.06 MPa
 Hydrogen Consumption: 7000 mL/min (atnominal power)

Environmental Characteristics:

 AmbientTemperature: -5 to +35 C
 Ambient Humidity: 10% RH to 95% RH (Nomisting)
 Storage Ambient Temperature: -10 to +50C
 Noise: <60 dB

Physical Characteristics:

 StackSize (mm): 205*168*90
 Stack Weight: 1.965 kg
 Controller Size (mm): TBD
 Controller Weight: TBD
 System Size (mm): 205*205*130
 System Weight: 2.590 kg.



Portable, Clean Power for Multiple Applications

Designed for versatility, the G-HFCS-600W24V serves as an ideal power source for outdoor applications, remote telecommunication setups, portable backup systems, and research development testing. Its reliable operation under a broad range of conditions ensures critical equipment stays powered in remote or challenging environments.


Efficient Hydrogen Utilization and Fast Start-Up

With fuel cell efficiency exceeding 50% (LHV) and a hydrogen consumption rate of just 0.35 Nm/h at full load, this generator maximizes power output while minimizing fuel use. Its swift start-up time under 60 seconds means you can access clean energy without delays, making it ideal for urgent power needs.


Advanced Protection and User Safety

The system integrates comprehensive protection featuresincluding overload, short-circuit, reverse polarity, and low fuel pressure safeguardsensuring safe operation. Constructed from corrosion-resistant composite metals and plastics, it provides safe, durable performance even in harsh conditions.

FAQs of G-HFCS-600W24V (600 W Hydrogen Fuel Cell Power Generator):


Q: How does the G-HFCS-600W24V hydrogen fuel cell generator operate?

A: The generator produces electricity by converting hydrogen fuel into electrical energy using a PEM (Proton Exchange Membrane) fuel cell core. It supplies 600W of power at a steady 24V DC output, suitable for various applications ranging from portable power to telecommunication backup.

Q: What are the main benefits of using this hydrogen fuel cell generator?

A: Key benefits include zero-emission clean power, fast start-up in under 60 seconds, quiet operation under 55 dB(A), fuel efficiency over 50%, and robust system protection against overload, short-circuit, and reverse polarity, ensuring reliability and safety.

Q: When is the G-HFCS-600W24V best utilized?

A: It is ideal for situations requiring portable or backup power, especially in remote outdoor locations or during emergencies, as well as for R&D testing where efficient, low-humidity operation is essential.

Q: Where can this generator be deployed in India?

A: It can be employed in remote telecom sites, outdoor monitoring stations, field research labs, disaster recovery locations, and anywhere a compact, clean, and mobile power solution is necessary.

Q: What is the process for starting and operating the generator?

A: To operate, supply 99.99% purity hydrogen fuel, ensure proper connections, and power it up. The system initiates within 60 seconds and requires minimal maintenance, thanks to air cooling and dry moisture handling.

Q: How is hydrogen consumption managed during usage?

A: At full load, the generator consumes approximately 0.35 Nm/h of hydrogen. Controlling operating conditions and maintaining proper fuel supply ensures optimal performance and efficiency.

Q: What protection features are included to safeguard the system?

A: The unit is engineered with safeguards against overload, short-circuit, reverse polarity, and low fuel pressure, each designed to protect both the user and equipment during operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fuel Cell Stacks Category

Flex-Stak Kit

Flex-Stak Kit

Purity : 99.9%

Material : HighGrade Polymer

Chemical Composition : Polypropylene, Additives

Product Type : Other, FlexStak Kit

Application : Other, Laboratory Storage & Organization

Color : Blue/Grey

Flow Battery Flex-Stak

Flow Battery Flex-Stak

Purity : High

Material : Highgrade Engineering Plastics, Graphite Plates, Membrane, Stainless Steel Fasteners

Chemical Composition : Varies by electrolyte (commonly Vanadiumbased or others)

Product Type : Other, Flow Battery Stack

Application : Other, Laboratory Research, Educational Demonstration, Energy Storage Testing

Color : Silver / Grey

Flex-Stak Expansion Kit

Flex-Stak Expansion Kit

Purity : High

Material : Industrial polypropylene plastic

Chemical Composition : Highgrade industrial polymers

Product Type : Other, Expansion Kit for Flexible Storage

Application : Other, Warehouse organization, Inventory management, Workshop utility

Color : Black

Syringe (Without Needle)

Syringe (Without Needle)

Purity : Sterile, nontoxic, pyrogenfree

Material : Polypropylene (PP), synthetic rubber gasket

Chemical Composition : Medical grade polypropylene (barrel and plunger), rubber or synthetic gasket

Product Type : Other, Medical syringe without needle

Application : Other, Liquid medication administration, fluid withdrawal, laboratory use, irrigation

Color : Transparent barrel with black measurement markings